What is a data center IDC computer room, and what equipment does the data center computer room include?

What is a data center IDC computer room?

     IDC provides large-scale, high-quality, safe and reliable professional server hosting, space rental, network wholesale bandwidth, ASP, EC and other services for Internet content providers (ICP), enterprises, media and various websites. IDC is the place where enterprises, merchants or website server groups are hosted; it is the infrastructure for the safe operation of various modes of e-commerce, and it also supports enterprises and their business alliances (its distributors, suppliers, customers, etc.) to implement value chains. managed platform.

     The data center is not only a network concept, but also a service concept. It constitutes a part of the basic network resources and provides a high-end data transmission service and high-speed access service.

     Simply put, IDC data center refers to a large computer room. It means that the telecommunications department uses the existing Internet communication lines and bandwidth resources to establish a standardized telecommunications professional-grade computer room environment to provide enterprises, institutions, government agencies, and individuals with all-round services in server hosting, leasing business, and related value-added services. By using the IDC server hosting service of China Telecom, enterprises or government units can solve many professional needs of using the Internet without building their own special computer rooms, laying expensive communication lines, and hiring network engineers with high salaries.

     IDC stands for Internet Data Center, which has developed rapidly along with the continuous development of the Internet, and has become an indispensable and important part of China’s Internet industry in the new century. It provides large-scale, high-quality, safe and reliable professional domain name registration query hosting (seat, rack, computer room rental), resource rental (such as virtual Host business, data storage service), system maintenance (system configuration, data backup, troubleshooting service), management service (such as bandwidth management, traffic analysis, load balancing, intrusion detection, system vulnerability diagnosis), and other support and operation services, etc. .

     The IDC data center has two very important features: the location in the network and the total network bandwidth capacity, which constitutes a part of the basic resources of the network, just like the backbone network and access network, it provides a high-end Data transmission services, providing high-speed access services.

What does the data center IDC computer room do?

     In a sense, the IDC data center evolved from the server hosting room of the ISP. Specifically, with the rapid development of the Internet, the website system has increasingly high requirements for bandwidth, management and maintenance, which poses a severe challenge to many enterprises. As a result, enterprises began to hand over everything related to website hosting services to IDC, which specializes in providing network services, and concentrated their energies on the business of enhancing their core competitiveness.

     At present, in order to solve the problem of north-south intercommunication, the IDC industry has developed the dual-line access technology of China Telecom and Netcom. The dual-line automatic switching of China Telecom and Netcom’s seven-layer full-routing IP strategy technology completely solves the data mutual load balance solution for the interconnection and interworking of China and China. In the past, two servers were placed in telecom and Netcom computer rooms for users to choose to visit, but now only one server is placed in a dual-line computer room to achieve fully automatic interconnection and mutual access of Telecom and Netcom. Single IP dual line completely solves the key problem of north-south intercommunication, making telecom and Netcom, north-south intercommunication no longer a problem, and greatly reduces investment costs, which is more conducive to the development of enterprises.

 What is a data center IDC computer room, and what equipment does the data center computer room include

What equipment is included in the data center computer room?

     The data center computer room belongs to the category of electronic information system computer room. Compared with the general electronic information system computer room, its status is more important, the facilities are more complete, and the performance is better.

     The construction of the data center computer room is a systematic project, which consists of the main computer room (including network switches, server clusters, storage, data input, output wiring, communication areas and network monitoring terminals, etc.), basic work rooms (including offices, buffer rooms, corridors, etc.) , dressing room, etc.), the first type of auxiliary room (including maintenance room, instrument room, spare parts room, storage medium storage room, reference room), the second type of auxiliary room (including low-voltage power distribution, UPS power supply room, battery room, precision Air-conditioning system rooms, gas fire extinguishing equipment rooms, etc.), the third type of auxiliary rooms (including storage rooms, general lounges, toilets, etc.).

     A large number of network switches, server groups, etc. are placed in the computer room, which is the core of integrated wiring and information network equipment, as well as the data aggregation center of the information network system. The cleanliness, temperature and humidity requirements are relatively high. There are a large number of supporting equipment such as UPS uninterruptible power supply, precision air conditioner, and computer room power supply installed in the computer room. It is necessary to configure an auxiliary computer room. , so that the area of the computer room is relatively large. In addition, independent entrances and exits should be set up in the layout of the computer room;

     When the entrance is shared with other departments, cross flow of people and logistics should be avoided, and personnel should change clothes and shoes when entering and exiting the main engine room and basic work room. When the computer room is built together with other buildings, separate fire compartments shall be set up. There should be no less than two safety exits in the computer room, and they should be located at both ends of the computer room as much as possible.

     Each system of the computer room is set according to the functional requirements, and its main projects include the decoration and environmental engineering of the computer room area, office area and auxiliary area; reliable power supply system engineering (UPS, power supply and distribution, lightning protection grounding, computer room lighting, backup power supply etc.); dedicated air conditioning and ventilation; fire alarm and automatic fire extinguishing; intelligent weak current projects (video surveillance, access control management, environment and water leakage detection, integrated wiring, KVM systems, etc.).


Post time: Dec-08-2022