Factory For 3RW 120-800K yokhala ndi 380VAC/400VAC/415VAC Input and Output Modular UPS Power Supply for Data Center
Kampani yathu yakhala ikuyang'ana kwambiri pamalingaliro amtundu. Kukhutira kwamakasitomala ndiko kutsatsa kwathu kwabwino kwambiri. Timaperekanso othandizira a OEM a Factory For 3RW 120-800K yokhala ndi 380VAC/400VAC/415VAC Input and Output Modular UPS Power Supply for Data Center, Njira yathu yapaderadera imachotsa kulephera kwa gawoli ndipo imapatsa ogula athu mosasinthasintha, zomwe zimatilola kuwongolera. mtengo, konzekerani mphamvu ndikusunga nthawi yopereka nthawi.
Kampani yathu yakhala ikuyang'ana kwambiri pamalingaliro amtundu. Kukhutira kwamakasitomala ndiko kutsatsa kwathu kwabwino kwambiri. Timaperekanso othandizira OEM kwaChina UPS ndi Modular UPS, Timapereka ntchito za OEM ndi magawo ena kuti tikwaniritse zosowa zosiyanasiyana za makasitomala athu. Timapereka mtengo wampikisano wazinthu zabwino kwambiri ndipo tidzatsimikiza kuti kutumiza kwanu kumayendetsedwa mwachangu ndi dipatimenti yathu yoyendetsera zinthu. Tikukhulupirira ndi mtima wonse kukhala ndi mwayi wokumana nanu ndikuwona momwe tingathandizire kupititsa patsogolo bizinesi yanu.
Mawonekedwe


Malangizo Ochepa
1. Mu nthawi ya chitsimikizo makinawo ali ndi vuto, chonde lemberani ogulitsa malonda, tidzakhala ndi udindo wothandizira makasitomala.
2. Kupitirira nthawi ya chitsimikizo, ntchito yosayenera ndi kuwonongeka kopangidwa ndi anthu, tidzaperekabe chithandizo ndi chithandizo, tidzapereka zida zosungira pamtengo wamtengo wapatali.
3. Malinga ndi zosowa za kasitomala, titha kupereka zosavomerezeka, koma mtengo ukhoza kukhala wokwera pang'ono kuposa makina achikhalidwe.
Mapulogalamu

Data processing Center, The host host, Computer servers, Medical, Traffic, Electricity, IT, Industrial ndi mafakitale ena.
Factory Production Line
Kupaka

Kampani yathu yakhala ikuyang'ana kwambiri pamalingaliro amtundu. Kukhutira kwamakasitomala ndiko kutsatsa kwathu kwabwino kwambiri. Timaperekanso othandizira a OEM a Factory For 3RW 120-800K yokhala ndi 380VAC/400VAC/415VAC Input and Output Modular UPS Power Supply for Data Center, Njira yathu yapaderadera imachotsa kulephera kwa gawoli ndipo imapatsa ogula athu mosasinthasintha, zomwe zimatilola kuwongolera. mtengo, konzekerani mphamvu ndikusunga nthawi yopereka nthawi.
Factory KwaChina UPS ndi Modular UPS, Timapereka ntchito za OEM ndi magawo ena kuti tikwaniritse zosowa zosiyanasiyana za makasitomala athu. Timapereka mtengo wampikisano wazinthu zabwino kwambiri ndipo tidzatsimikiza kuti kutumiza kwanu kumayendetsedwa mwachangu ndi dipatimenti yathu yoyendetsera zinthu. Tikukhulupirira ndi mtima wonse kukhala ndi mwayi wokumana nanu ndikuwona momwe tingathandizire kupititsa patsogolo bizinesi yanu.
| CHITSANZO | BNT9010S(H)-33* | BNT9020S(H)-33* | BNT9030S(H)-33* | BNT9040S(H)-33* | BNT9060H-33 | BNT9080H-33 | BNT9100H-33 | BNT9120H-33 | BNT9160H-33 | BNT9200H-33 | |
| PHASE | 3-gawo mu / 3-gawo kunja | ||||||||||
| KUTHA | 10 kVA / 9 kW | 20kVA / 18KW | 30kVA/27KW | 40KVA/36KW | 60KVA/54KW | 80kVA/72KW | 100kVA/90KW | 120kVA/108KW | 160kVA/144KW | 200kVA/180KW | |
| KUTHANDIZA KWAMBIRI | mpaka mayunitsi atatu molumikizana | mpaka 2 mayunitsi ofanana | |||||||||
| INPUT | |||||||||||
| Nominal Voltage | 3 x 400 VAC (3Ph+N) | ||||||||||
| Mtundu wa Voltage | 190-520 VAC (3-gawo) @ 50% katundu; 305-478 VAC (3-gawo) @ 100% katundu | 208-478 VAC (3-gawo) @ 70% katundu; 305-478 VAC (3-gawo) @ 100% katundu | |||||||||
| Nthawi zambiri | 46 ~ 54 Hz kapena 56 ~ 64Hz | 40-70Hz | |||||||||
| Mphamvu Factor | ≧ 0.99 @ 100% Katundu | ||||||||||
| ZOPHUNZITSA | |||||||||||
| Kutulutsa kwa Voltage | 3 x 360*/380/400/415 VAC (3Ph+N) | 3 x 380/400/415 VAC (3Ph+N) | |||||||||
| AC Voltage Regulation (Batt. Mode) | ± 1% | ||||||||||
| Ma frequency Range (msinkhu Wolumikizana) | 46 ~ 54Hz kapena 56 ~ 64Hz | ||||||||||
| Nthawi zambiri (Batt. Mode) | 50 Hz ± 0.1 Hz kapena 60 Hz ± 0.1 Hz | ||||||||||
| Current Crest Ration | 3:1 (max.) | ||||||||||
| Kusokonezeka kwa Harmonic | ≤2 % THD (Linear Katundu); ≤4 % THD (Katundu Wopanda mzere) | ≤2 % THD (Linear Katundu); ≤4 % THD (Katundu Wopanda mzere) | |||||||||
| Nthawi Yosamutsa | Zero | ||||||||||
| Inverter kupita ku Bypass | Zero | ||||||||||
| Waveform (Batt. Mode) | Pure Sine wave | ||||||||||
| Zochulukira | AC Mode | 100-110% kwa mphindi 10, 110-130% kwa mphindi imodzi,> 130% kwa mphindi imodzi | 105-110% kwa 1 hr, 111-125% kwa 10 min, 126-150% kwa 1 min,> 150% kwa 200ms | ||||||||
| Battery Mode | 100-110% kwa masekondi 30, 110-130% kwa masekondi 10, | 105-110% kwa 1 hr, 111-125% kwa 10 min, 126-150% kwa 1 min,> 150% kwa 200ms | |||||||||
| KUGWIRITSA NTCHITO | |||||||||||
| AC Mode | 95.50% | 94.00% | |||||||||
| Njira ya ECO | 97.00% | 98.00% | |||||||||
| Battery Mode | 93.50% | 93.00% | |||||||||
| BATIRI | |||||||||||
| Standard Model | Nambala | (16+16) pcs x 1 chingwe | (16+16) pcs x 2 zingwe | N / A | |||||||
| Nthawi Yowonjezera Yowonjezera | Maola 9 amachira mpaka 90%. | ||||||||||
| Kulipira Panopa (max.) | 1A/2A/3A/4A (Zosintha) | ||||||||||
| Kuthamangitsa Voltage | +/- 218 VDC ± 10% | ||||||||||
| Mtundu Wautali | Mtundu Wabatiri | Malinga ndi mphamvu ya kunja mabatire | |||||||||
| Nambala | 32 ~ 40 pcs (zosinthika) | ||||||||||
| Kulipira Panopa (max.) | 1A/2A/3A/4A (Yosinthika)Yofanana mpaka 3 ma charger board kuti ifikire 12A pazipita | 2A/4A/6A/8A (Yosinthika) Yofanana mpaka ma seti 3 a ma board a charger apawiri kuti afike 24A pazipita | 24A | 32A | 40 A | 48A | |||||
| Kuthamangitsa Voltage | +/- 13.65V x N (N=16~20) | +/- 13.7V x N (N = 16~20) | |||||||||
| ZIZINDIKIRO | |||||||||||
| Chiwonetsero cha LCD | Mkhalidwe wa UPS, Mulingo wa Katundu, Mulingo wa Battery, Magetsi Olowetsa/Otulutsa, Nthawi Yotulutsa, ndi Zolakwika | 10" Touch Type mtundu wa LCD | |||||||||
| ZATHUPI | |||||||||||
| Standard Model | kukula, D x W x H (mm) | 627 x 250 x 750 | 815 x 300 x 1000 | N / A | |||||||
| Net Weight (kg) | 129 | 144 | 225 | 250 | |||||||
| Mtundu Wautali | kukula, D x W x H (mm) | 627 x 250 x 750 | 815 x 300 x 1000 | 790 x 360 x 1010 | 940 x 567 x 1015 | 1040 x 567 x 1452 | |||||
| Net Weight (kg) | 33 | 48 | 60 | 61 | 108 | 113 | 199 | 234 | 306 | 340 | |
| DZIKO | |||||||||||
| Kutentha kwa Ntchito | 0-40 ° C | ||||||||||
| Ntchito Chinyezi |
| ||||||||||
| Mlingo wa Phokoso | Pansi pa 55dB@1 mita | Pansi pa 60dB@1 Meta | Pansi pa 70dB @ 1 mita | Pansi pa 75dB@1 Meta | Pansi pa 70dB @ 1 mita | Pansi pa 73dB @ 1 mita | |||||
| MANAGEMENT | |||||||||||
| Smart RS-232 / USB | Imathandizira Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux ndi MAC | ||||||||||
| Mwasankha SNMP | Kuwongolera mphamvu kuchokera kwa manejala wa SNMP ndi msakatuli | ||||||||||