Ndị na-ere ahịa nke Le Durable Ụdị Germany 19 Inch Rack PDU Data Center
Anyị na-ewere "ndị ahịa-enyi na enyi, mma-gbakwasara, mwekota, ọhụrụ" dị ka ebumnobi. "Eziokwu na ịkwụwa aka ọtọ" bụ njikwa anyị dị mma maka ndị na-ere ahịa n'ogbe nke Le Durable Type Germany 19 Inch Rack PDU Data Center, Anyị nwere ike ịnye gị otu n'ime ọnụ ahịa ire ere kachasị asọmpi na ezigbo mma, n'ihi na anyị emeela ọtụtụ ihe ruru eru! Yabụ na ị gaghị egbu oge ịkpọ anyị.
Anyị na-ewere "ndị ahịa-enyi na enyi, mma-gbakwasara, mwekota, ọhụrụ" dị ka ebumnobi. "Eziokwu na eziokwu" bụ njikwa anyị dị mma makaChina PDU na 19 inch, Ụlọ ọrụ anyị na-agbaso echiche nchịkwa nke "na-edebe ihe ọhụrụ, na-achụso mma". Na ndabere nke na-emesi uru nke ngwọta dị ugbu a, anyị na-anọgide na-ewusi ike na ịgbatị mmepụta ngwaahịa. Ụlọ ọrụ anyị na-ekwusi ike na ihe ọhụrụ iji kwalite mmepe mmepe nke ụlọ ọrụ, ma mee ka anyị bụrụ ndị na-ebubata ihe dị elu nke ụlọ.
Atụmatụ



Nhọrọ oghere

Nhọrọ nkwụnye


Isi uru
A. Njikwa netwọk dịpụrụ adịpụ
a. Njikwa Cascade (SNMP V1.V2.V3)
b. Njikọ Wifi
c. Ngosipụta eserese data d. Njikwa onye ọrụ
e. echekwara ndekọ ahụ
f. Otutu ọnọdụ mkpu g. Njikwa nnweta, site na telnet, ssh ma ọ bụ modbus-rtu h. Nhọrọ mmepụta ọtụtụ
B. Ọrụ nlekota oru
a. Nlebanya ntinye voltaji b. Nyochaa mkpokọta ibu ugbu a
c. Nleba anya mkpokọta ike (KW)
d. Nleba anya oriri ike (KWH)
e. Ngụkọta ikike ịkwọ ụgbọala
f. Nleba anya nke ọ bụla ntinye ike
g. Gbakọọ nkeji ọ bụla oriri ike
C. Ọrụ njikwa
a. Njikwa ngbanwu/ gbanyụọ maka ọpụpụ ọ bụla
b. Ntọala oge ịgbanyụ / gbanyụọ maka ntinye ọ bụla
c. Ntọala igbu oge buut
d. Tọọ oke ugbu a maka ntinye ọ bụla
e. Nchekwa oke ibu (mgbanyụ ọkụ na-akpaghị aka)

Ngwa

Ngwa: Ụlọ ụbọchị, Ụlọ ọkụ ọkụ, Engine Room, Financial Center, Education Institution, Production Environment, Ngwuputa Ugbo.
Line Production Line
Nkwakọ ngwaahịa

Anyị na-ewere "ndị ahịa-enyi na enyi, mma-gbakwasara, mwekota, ọhụrụ" dị ka ebumnobi. "Eziokwu na ịkwụwa aka ọtọ" bụ njikwa anyị dị mma maka ndị na-ere ahịa n'ogbe nke Le Durable Type Germany 19 Inch Rack PDU Data Center, Anyị nwere ike ịnye gị otu n'ime ọnụ ahịa ire ere kachasị asọmpi na ezigbo mma, n'ihi na anyị emeela ọtụtụ ihe ruru eru! Yabụ na ị gaghị egbu oge ịkpọ anyị.
Ndị na-ere ahịa n'ogbe nkeChina PDU na 19 inch, Ụlọ ọrụ anyị na-agbaso echiche nchịkwa nke "na-edebe ihe ọhụrụ, na-achụso mma". Na ndabere nke na-emesi uru nke ngwọta dị ugbu a, anyị na-anọgide na-ewusi ike na ịgbatị mmepụta ngwaahịa. Ụlọ ọrụ anyị na-ekwusi ike na ihe ọhụrụ iji kwalite mmepe mmepe nke ụlọ ọrụ, ma mee ka anyị bụrụ ndị na-ebubata ihe dị elu nke ụlọ.
| Njirimara ntinye | |
| Ntinye voltaji | Otu nkeji 240V (LNG) ruo 240V Otu usoro |
| 380V 3 Phase (LLLNG) ruo 220V Otu Usoro | |
| 415V 3 Phase (LLLNG) ruo 240V Otu Usoro | |
| 433V 3 Phase (LLLNG) ruo 250V Otu Usoro | |
| Njikọ ntinye | 150Ax5wires (ma ọ bụ igbe nkwụsị, nhọrọ ntinye ntinye) |
| ugboro ugboro | 50/60Hz |
| Mgbakọta ugbu a | Oke 125A |
| Voltage mmepụta ọkwa | 208-300VAC |
| Ike mmepụta kacha maka ọpụpụ ọ bụla | N'okpuru 208V, Max 3328W kwa ntinye |
| N'okpuru 240V, Max 3840W kwa ntinye | |
| N'okpuru 250V, Max 4000W kwa ntinye | |
| Mkpokọta ike mmepụta | Oke 4432Wx24 |
| Ọkọlọtọ Socket | 12pcs C19 (ahaziri) |
| Njikwa anya | TCP/IP, Igwe njikwa ọkụ-swap |
| Njiji | 125A 3P mebiri emebi na UL ma ọ bụ CE |
| Nkọwa waya | Asambodo UL, yana ọrụ retardant ọkụ |
| Nwalee ihe | |
| Nnwale Hi-pot | GAAFE |
| Nnwale ịgbasa nnu | GAAFE |
| Ule ala | GAAFE |
| Nnwale polarity | GAAFE |
| Nnwale IR | GAAFE |
| Nnwale Ndụ Socket | GAAFE |
| Ule ịka nká | GAAFE |
| Agba & ihe onwunwe | |
| Agba ngwaahịa | Silver na-acha ọcha ma ọ bụ oji |
| Ngosipụta ire ọkụ plastik | UL94V-0 ọkwa |