Comprehensive strategy for extending the life of UPS

2025-04-10

The life of UPS (uninterruptible power supply) is usually designed to be 5-10 years, but it can be extended to longer through scientific maintenance.

The following are the core methods to extend the life of UPS power, combined with multi-dimensional optimization such as environmental management, usage habits, and maintenance technology:

1.Optimize the operating environment

Temperature and humidity control

Ideal temperature: 20-30℃, and the battery life decreases by about 5% for every 1℃ increase in temperature. High temperature accelerates the evaporation of electrolyte, and low or excessive temperature will also affect the activity of the battery.

Humidity management: Relative humidity is controlled at 40%-60% to avoid condensation or excessive drying that causes component corrosion.

Ventilation and dust prevention: Regularly clean the dust around the UPS to ensure that the heat dissipation holes are unobstructed to avoid dust accumulation causing short circuits or poor heat dissipation.

Power environment adaptation

Voltage range: Select a UPS with a wide input voltage range (such as 160-278V AC) to adapt to grid fluctuations.

Lightning protection: Install a lightning protection module to prevent lightning strikes or surge voltages from damaging the internal circuit.

2.Scientific usage habits

Load management

Load rate control: The load of the backup UPS shall not exceed 60%, and the load of the online UPS shall not exceed 80%. Long-term overload will shorten the battery life.

Avoid inductive loads: For equipment with large starting current such as motors and compressors, it is necessary to calculate the use of a UPS with a larger capacity, otherwise the instantaneous current may exceed the rated value, causing damage to the inverter.

Charging and discharging strategy

Regular deep discharge: Fully discharge once every 2-3 months (to 20%-30% power) to prevent battery passivation.

Avoid excessive discharge: The discharge depth is controlled within 80%, otherwise it may cause irreversible damage to the battery.

Smart charging: Use three-stage charging (constant current → constant voltage → floating charge) to avoid overcharging or undercharging.

uninterruptible power supply.jpg

3.Special battery maintenance

Battery status monitoring

Internal resistance test: Use professional instruments (such as Fluke BT521) to detect the internal resistance of the battery every quarter. If the internal resistance exceeds 50% of the initial value, it needs to be replaced.

Voltage balance: Multi-cell battery packs need to be charged regularly to prevent the voltage difference of a single cell from causing overall performance degradation.

4.Regular maintenance and inspection

Hardware maintenance

Cleaning and tightening: clean the internal dust every quarter, check whether the terminals are oxidized or loose, and use rust inhibitor to treat metal parts.

Cooling system inspection: fans and heat sinks need to be dusted regularly to ensure heat dissipation efficiency and avoid high temperature causing component aging.

Function test

Self-test mode: start the UPS self-test function every month, simulate power-off switching, and verify the response speed of the inverter and battery.

Bypass test: test the maintenance bypass function every year to ensure that the load is seamlessly switched to the mains during maintenance.

Replacement and upgrade

Life cycle: lead-acid battery life is 3-5 years, and lithium battery can reach 8-10 years. Replace when the capacity drops to 80%.

Compatibility selection: choose batteries of the same brand, model and capacity when replacing, and avoid mixing new and old.

5.Other key considerations

Avoid frequent switching on and off

Frequent switching on and off accelerates capacitor aging, and the interval between two starts needs to be ≥6 seconds.

Intelligent monitoring and early warning

Use SNMP or manufacturer software to monitor load and battery status in real time and set threshold alarms.

Choose reliable brands and models

Industrial scenarios prefer industrial frequency online UPS, which outputs pure sine waves, has strong anti-interference ability, and has a built-in isolation transformer.

Summary: The core logic of extending life

The combination of reducing external damage through environmental optimization, reducing internal losses through scientific use, and eliminating hidden dangers in advance through regular maintenance can maximize the extension of UPS life.

For high-value equipment, it is recommended to adopt a modular UPS design that supports hot-swap replacement of faulty components to reduce the risk of downtime.